Sterile Setup Table in the Operating Room Is Not So Sterile


Najafi F., Fernandez- Rodriguez D., Parvizi J.

JOURNAL OF ARTHROPLASTY, cilt.38, sa.3, ss.562-0, 2023 (SCI-Expanded) identifier identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 38 Sayı: 3
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1016/j.arth.2022.09.019
  • Dergi Adı: JOURNAL OF ARTHROPLASTY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aerospace Database, CINAHL, Communication Abstracts, MEDLINE, Metadex, Civil Engineering Abstracts
  • Sayfa Sayıları: ss.562-0
  • Acıbadem Mehmet Ali Aydınlar Üniversitesi Adresli: Hayır

Özet

Background: One of the important factors for surgical site infection prevention is the implementation of an ultraclean operating room. This study was designed to evaluate back-table sterility during total joint arthroplasty.Methods: This prospective study includes 52 patients undergoing primary total joint arthroplasty between November 2021 and January 2022. A total of 4 swabs (2 air swabs and 2 table swabs) were obtained for each case, at the conclusion of surgery and prior to the takedown of drapes. One swab from each set was sent for culture, and the other was sent for next-generation sequencing (NGS) analysis.Results: Among 104 back-table swabs, a total of 13 (12.5%) organisms were isolated. Of these, 7 organ-isms were isolated by culture and 6 by NGS. No microorganisms were isolated by both culture and NGS from back-table swabs. Among 104 air swabs, a total of 11 (10.6%) organisms were isolated. Of these, 6 microorganisms were isolated by culture and 5 by NGS. In 4 of the 104 swabs, both culture-and NGS-isolated organisms were from air swabs. Of the 104 (12.5%) back-table and air swabs, 13 were culture positive. While more than 1 pathogen was identified in 2 air swabs, all back-table swabs were mono -microbial by culture. Pathogens were identified from 11 of 104 (10.6%) swabs by NGS, while more than 1 pathogen was identified in 4 swabs (2 air and 2 back table). Conclusion: The findings of this study raise an important issue that the surgical field including the sterile table setup for instruments is not "sterile" and can harbor pathogens.(c) 2022 Elsevier Inc. All rights reserved.