Lateral Harvest of an Osseous-Based Quadriceps Tendon Autograft Results in Thinner Remaining Patellar Bone


Perry A. K., Dandu N., Knapik D. M., Inoue N., Gursoy S., Bush-Joseph C. A., ...Daha Fazla

ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, cilt.10, sa.5, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 10 Sayı: 5
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1177/23259671221093685
  • Dergi Adı: ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, Directory of Open Access Journals
  • Acıbadem Mehmet Ali Aydınlar Üniversitesi Adresli: Hayır

Özet

Background: Patellar fracture after quadriceps tendon (QT) autograft harvest for anterior cruciate ligament reconstruction (ACLR) has been reported in up to 8.8% of patients. Purpose: To determine the thickness of the remaining patellar bone across the QT graft harvest location while providing clinical guidance for safely harvesting a patellar bone block when using a QT graft in ACLR. Study Design: Descriptive laboratory study. Methods: Medial and lateral QT graft boundaries were marked using a bone saw on 13 cadaveric patellae, and 3-dimensional computed tomography models were created. After the harvest of a virtual bone block with a maximum depth of 10 mm, the thickness of the remaining bone was measured across the graft harvest location in 9 zones. The thickness of the remaining bone was analyzed according to zone, graft harvest location, and patellar facet length. Risk zones were defined as Results: We observed substantial variability in QT bone block harvest location, in which the distance between the lateral boundary of the harvest location and the lateral patellar cortex was from 21.2% to 49.2% of the axial patellar width. There was significantly less bone remaining in the lateral columns (mean +/- SD, 7.56 +/- 2.19 mm) compared with the medial columns (9.83 +/- 2.10 mm) of the graft harvest location (P = .028). The number of risk zones was significantly associated with distance to the lateral cortical edge, with an increase in 0.59 zones with every 1-mm decrease in distance to the lateral cortex edge (b = -0.585; R (2) = 0.620; P = .001). With every 1-mm increase in the distance of the lateral cortex to the lateral graft boundary, the thickness of bone remaining in the lateral column increased by 0.412 mm (P < .001). No risk zones were encountered when the lateral boundary of the harvest location was created 18.9 mm from the lateral edge of the patella or 43% of the total patellar width from the lateral edge. Conclusion: Harvest of a more laterally based QT autograft bone block resulted in thinner remaining patellar thickness, increasing the potential of encountering a risk zone for fracture.