Functional and radiologic results of extensor mechanism reconstruction methods following proximal tibial modular endoprosthetic reconstructions: Direct versus medical textile augmented reattachment.


Aycan O. E. , Alpan B. , Özmen E., Valiyev N., Özger N. H.

The Knee, vol.30, pp.337-343, 2021 (Journal Indexed in SCI) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 30
  • Publication Date: 2021
  • Doi Number: 10.1016/j.knee.2021.04.020
  • Title of Journal : The Knee
  • Page Numbers: pp.337-343
  • Keywords: Modular endoprosthetics, Malignant bone tumors, Extensor mechanism reconstruction, Medical textile augmented reattachment, PATELLAR TENDON, KNEE, RESECTION, SARCOMA, REPLACEMENT, SURGERY, TUMORS, MESH

Abstract

Background: Following proximal tibial resection and modular endoprosthetic reconstruction, extensor mechanism can be reconstructed with different techniques. This study compares direct reattachment (DR) with medical textile augmented reattachment (MTAR) methods in terms of functional results and radiological results.