Reliability of Observer-Based 3D Corrected Glenoid Version Measurements and Comparison With Blueprint Software
Aim & Background
Accurate measurement of glenoid version is essential for preoperative planning in shoulder arthroplasty. Although automated planning software such as Blueprint is increasingly used, the reliability and accuracy of its glenoid version measurements remain uncertain.
Background
Methods
Preoperative CT scans of 26 patients were analyzed. Glenoid version was measured independently by two observers using a three-dimensional (3D) correction technique. Each observer performed two measurements separated by a two-week interval. Intra-observer and inter-observer reliability were assessed using intraclass correlation coefficients (ICC) with absolute agreement. Blueprint software measurements were compared with the observers’ second measurements using paired statistical tests and Bland–Altman analysis.
Results
Intra-observer reliability was excellent for both observers (Observer 1 ICC = 0.98; Observer 2 ICC = 0.96). Inter-observer agreement between second measurements was also excellent (ICC = 0.94). Blueprint software measurements differed significantly from observer-based 3D corrected measurements for both observers (p < 0.001). Bland–Altman analysis demonstrated a systematic bias, with Blueprint consistently reporting greater glenoid retroversion and wide limits of agreement. These findings indicate that the observed differences were not merely statistical but reflected a method-related and clinically relevant measurement bias.
Conclusion
Observer-based, 3D-corrected glenoid version measurements demonstrated excellent reliability. By contrast, Blueprint software measurements showed significant and systematic deviation from observer measurements, raising concerns about the accuracy of automated glenoid version assessment when used as the only reference. Inaccurate assessment of glenoid version may directly influence implant positioning, correction of retroversion, and the risk of postoperative complications. Therefore, reliance solely on automated software measurements may alter surgical decision-making and implant selection in shoulder arthroplasty.