Percutaneous removal of two intracardiac and pulmonary trunkal catheter fragment by using a snare-loop catheter


Dagdelen S., Yuce M., Caglar N.

INTERNATIONAL JOURNAL OF CARDIOLOGY, vol.116, no.3, pp.413-415, 2007 (SCI-Expanded, Scopus)

  • Publication Type: Article / Letter
  • Volume: 116 Issue: 3
  • Publication Date: 2007
  • Doi Number: 10.1016/j.ijcard.2006.06.010
  • Journal Name: INTERNATIONAL JOURNAL OF CARDIOLOGY
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.413-415
  • Acibadem Mehmet Ali Aydinlar University Affiliated: Yes

Abstract

Endoluminal retrieval of foreign bodies in the cardiac laboratory is an uncommon and challenging procedure for the endovascular specialist, and its only alternative is an open exploration. The availability of smaller catheter systems allows retrieval with minimally invasive techniques. We report retrieval of two catheter fragments using a snare-loop catheter through the femoral vein. (c) 2006 Elsevier Ireland Ltd. All rights reserved.