Rapid detection of serum free light chains by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.


Kaya Z. Z., Serdar M. A., Aksungar F., Kilercik M., Serteser M., Baykal A. T.

European journal of mass spectrometry (Chichester, England), cilt.29, sa.2, ss.132-140, 2023 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 29 Sayı: 2
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1177/14690667231153616
  • Dergi Adı: European journal of mass spectrometry (Chichester, England)
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, Compendex, EMBASE, INSPEC, MEDLINE
  • Sayfa Sayıları: ss.132-140
  • Anahtar Kelimeler: Free light chains, MALDI-TOF MS, method comparison, micro-affinity chromatography, plasma cell disorders
  • Acıbadem Mehmet Ali Aydınlar Üniversitesi Adresli: Evet

Özet

Introduction: Serum free light chain (FLC) measurements are increasingly prominent for patients with plasma cell disorders (PCDs) in screening, prognostic stratification, and monitoring therapy responses. Objectives: We aimed to develop a sensitive, reliable, and accurate method for diagnosing PCDs that can notably decrease the time and cost of current methods. Methods: Here, we present a novel approach for FLC measurement using immunoenrichment on micro-affinity chromatography in combination with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) detection. In this study, serum free kappa (κ) and free lambda (λ) light chain (LC) levels in the serum of 105 patients were compared between the nephelometric serum FLC quantification and MALDI-TOF MS detection. Results: Cohen's kappa coefficient between the MALDI-TOF MS-based method and the FLC assay revealed an almost perfect agreement in the case of normal (negative) results (κ = 0.92; 95% confidence interval (CI): 0.837 to 0.968) and a good agreement in the case of increased (positive) results (κ = 0.76; 95% CI: 0.608 to 0.870). In Spearman's correlation analysis, the best correlation was found between serum free κ/λ ratios (r = 0.628, 0.496 to 0.732; p <0.0001). Our method showed sensitivity (92.5%) and specificity (76.3%) for discrimination between the κ/λ FLC ratio compared to the serum FLC assay. Conclusion: The proposed method can significantly contribute to diagnosing and monitoring PCDs as it can significantly be time-saving, cost-effective in FLC measurement.